You are here: Maintenance > Operator Routine Maintenance > Weekly > Clean and Inspect the Saw Chamber Door

Clean and inspect the saw chamber door

WHAT YOU NEED 

Safety Equipment:Standard Personal Protective Equipment

Other Equipment:Microfibre clothWarm soapy water or Windex

  1. Using the Manual Mode window, move the saw blade to the back of the saw chamber.
  2. Press the E‑stop button on the operator console.
  3. Open the saw chamber door.
  4. Start the dust extractor manually by pressing the ON button on the dust extractor control panel.
  5. Blow off any loose dust or swarf on and around the door.
  6. Stop the dust extractor manually by pressing the OFF button on the dust extractor control panel.
  7. Clean off any remaining dust and built-up grime with the microfibre cloth and warm soapy water. You may soak problem areas for several minutes if required.

    CAUTIONDo not use anything but a microfibre cloth or this will scratch the surface of the door and cause it to become cloudy.Do not use harsh cleaning products or strong solvents (e.g. acetone) or this will cause the door to become cloudy, brittle and more susceptible to damage.

  8. Perform a thorough visual inspection for any bubbles or cracks, paying close attention to the bend in the door.

    Note: Please contact Vekta Automation immediately if any defects are found in the door. It will need to be replaced as soon as possible.

  9. Shut the saw chamber door.
  10. Release the E‑stop button on the operator console.